LINEDESK
All sections
Belt changeVision 9002426-066-2p.52

Infeed conveyor belt change

Relieve tension, 10-32 plexi, 1/4-20 end plate, swap belt.

A white belt and a black belt are provided. Choose contrast for the caps in use.

STEP 1: Remove belt tension. Loosen and remove the two fasteners at the end of the conveyor (loosen or remove the guard if needed). Also loosen and remove the two 10-32 fasteners underneath.

STEP 2: Loosen the two (2) lock nuts and bolts.

STEP 3: Remove the four (4) 10-32 bolts, then remove the Plexi guard covering the end plate.

STEP 4: Loosen and remove the six (6) 1/4-20 bolts, then remove the end plate.

With everything loose, fidget the belt off and replace it. Reinstall hardware in reverse order.